Standard Material Test Protocol

CentriFlow Meter

Name:

Email Address:

Subject:

Address line one:

Address line two:

Phone Number:

Work Phone:

Date:

Customer:

Test Equipment Setup: See below for drawing.


Customer's Installation Information:
(to be filled out by Customer)
Material to Test:

Density:
(lb/ft°)
Maximum Flow Rate
(lb/hr)
Average Flow Rate
(lb/hr)
Minimum Flow Rate
(lb/hr)
Feed System:

Discharge System:



Test Protocol:

I. Equilibrate: Material batches of 10 to15 gallons will be run through meter 10 times to equilibrate the unit. Equilibrate means allowing the material to build up on the measurement surfaces to a point where the material can not build up any further.

II. Calibration: Run five 10 to 15 gallon batches of material through the meter and record the meterfs mass flow output versus the weight of each batch falling into a weighing bucket as measured on a certified scale. Take the average differential between meterfs mass flow output and the scale readings and determine the calibration voltage offset. Adjust the calibration voltage accordingly.

III. Test: Run five 10 to 15 gallons batches of material through the meter at the desired rate(s) and record the meterfs mass flow output. Record the weight of each batch falling into a weighing hopper as measured on a certified scale.

IV. Calculate Accuracy as a percent of Reading. Calculate Standard Deviation.



Test Costs (Customer to check off one of the following):
Testing at one flow rate; we match the percent of volumetric flow, full scale, for the test meter that the customerfs actual sized meter will see. Test Charge: 0 *

Testing at two flow rates; (75 to 100%, and 30 to 50% of volumetric flow). Test Charge: 0 *

Testing at three flow rates; (80 to 100%, 50 to 70%, and 20 to 40% of volumetric flow). Test Charge: 0*

Video tape the test; a VHS format tape will be furnished: 0.

* If the customer decides to purchase a meter(s) within 90 days of the test, the test charge, less 0, will be deducted from the purchase of the first meter.

Sign Here after filling in all fields



Test Set-up A

NON-STANDARD SET-UP
VibraWeigh™ Option
Angled Installation
Reverse Feed
Extended Feed Time




Test Set-up B

NON-STANDARD SET-UP
VibraWeigh™ Option
Extended Feed Time




Test Set-up C

NON-STANDARD SET-UP
VibraWeigh™ Option
Extended Feed Time




Test Set-up D

NON-STANDARD SET-UP
VibraWeigh™ Option
Angled Installation
Reverse Feed
Extended Feed Time




Test Set-up E

NON-STANDARD SET-UP
VibraWeigh™ Option
Extended Feed Time